Transducers used in the Cardiac Ultrasound Machine.
Transducers employ in the Cardiac echography Machine.Transducers used in the Cardiac sonography Machine.Abstract Ultrasound mental imagery depends on the ability of piezoelectric automobile crystals to generate sound when excited with alternate(a) current and the reverse event of charge accumulation or current flow when such crystals argon subjected to wring from sound waves. The first known sonography imaging machine was intentional by K. T. Dussik in Australia in 1937. However, despite its widespread acceptance today, medical examination echography did not develop as rapidly as X-ray imaging. contempt the relatively slow start, medical ultrasonography imaging is real widely accepted today because there is no ionising radiation involved and hence the surgical operation is relatively safe. Ultrasound equipment is overly cheaper as compared to X-ray imaging, magnetic resonance imaging, MRI and other techniques associated with nuclear medicine. The procedure involves mi nimal patient discomfort and is very useful for examining the soft threads or the developing foetus. A dramatic increase in the number of older patients with chronic heart and valve disease has conclusioned in a prolific demand for the echography cardiac imaging machines which can satisfy the requirements associated with fast and cost effective measurement of cardiac anatomy or function. nonpareil of the critical elements in the medical ultrasonography imaging system is the ultrasound transducer without which signal bear on and visualisation of the soft tissue images is impossible. Although many naturally occurring substances such as quartz exhibit the piezoelectric effect, blend zirconate titanate (PZT) ceramic ferroelectric satisfyings energise for many years been used for biomedical applications because of their superior characteristics for soft tissue imaging. Polyvinylidene difluoride (PVDF), transducer stuff and nonsense has demonstrated advantages as a high oftennes s receiver. Single or multilayer transducers make of these elements can be used for ultrasound imaging as virtuoso transducers operating in A-mode or a 2 or ternion dimensional transducer array for B-mode, C-mode or M-mode ultrasound imaging. This brief essay takes a hold back at transducers for medical ultrasound.The principle of operation of a cardiac ultrasound imaging device is based on the information that is provided by the varying clutch measures of echoes that are reflected from various depths of the human embody tissue as a result of the ultrasound pulses that are generated by an ultrasound transducer universe hazard on the body tissue. Delay times of echoes from different depths are different and ultrasound is reflected from the interface of different types of tissues. A Doppler shift in frequency is overly generated as a result of moving objects and the attenuation of ultrasound waves depends on the type of tissue that the ultrasound wave is travelling through. T he ultrasound transducer which is responsible for the genesis and get holdion of reflected ultrasound is, therefore, an essential component of the ultrasound imaging device. Ultrasound transducers work on the basis of the piezoelectric effect in which an alternate(a) potential applied to piezoelectric crystal material causes the crystals to become electrically polarised as a result of the applied electric field and hence vibrate with the alternating voltage to produce sound. Such crystals also become electrically polarised when stress is applied to them and hence any sound waves which are incident on them result in charge accumulation on the crystal surface and hence the generation of an alternating voltage. Thus, an ultrasound transducer consists of a suitable piezoelectric material sandwiched between electrodes that are used to provide a fluctuating electric field when the transducer is required to generate ultrasound. When the transducer is required to detect ultrasound, the e lectrodes may be used to detect any fluctuating voltages produced as a result of the polarisation of the crystals of the piezoelectric material in response to incident sound which generates fluctuating mechanical stresses on the material. piezoelectric materials include quartz, ferroelectric crystals such as tourmaline and Rochelle salt as well as the group of materials known as the piezoelectric ceramics, which include lead titanate (PbTiO3) and lead zirconate (PbZrO3). These materials are also known as piezoelectric ceramics which are used in ultrasound transducers for biomedical applications.Polyvinylidene difluoride (PVDF) is another transducer material which has demonstrated advantages as a high frequency receiver. Piezoelectric ceramics are sold with the brand name PXE by Philips Company and are solid solutions of lead titanate (PbTiO3), and lead zirconate (PbZrO3) which have been circumscribed by additives which are a group of piezoelectric ceramics known as PZT. PXE materia ls are hard, chemically inert and unaffected by a humid environment.The crystals in a ferroelectric material of which PXE is made up of align themselves randomly in a number of directions. With such a random orientation of crystals, the material pull up stakes exhibit no piezoelectric effect. In disposition to have a piezoelectric material which is undefendable of being used for ultrasound transducers, the material has to be subjected to a strong electric field at high temperatures. This has the effect of permanently locking the crystals in the direction of the applied electric field and devising the crystal piezoelectric in the direction of the electric field. Hence, a piezoelectric ceramic material may be converted into a piezoelectric material in any given direction by applying a strong electric field to the material in the given direction at an elevated railroad temperature. This treatment, which is known as poling, is the final stage in the manufacture of a PXE piezoelectr ic. Metal electrodes perpendicular to the poling axis are deposited on the material so that an alternating electric field may be applied to generate ultrasound or ultrasound vibrations may be sensed by sensing the electric field across the piezoelectric material. The voltage across a piezoelectric ceramic PXE material is usually directly proportional to the applied stress. The construction of a simple, single element piezoelectric transducer is as shown below.The Construction of a Single Element Piezoelectric TransducerUltrasound imaging in the A-mode directs a narrow institutionalise of ultrasound into the tissue being scanned and the echo which may be displayed on a CRT screen provides a measure of the distance between reflecting surfaces in the body. In the B-scan mode, the echo signal is brightness modulated which makes it possible for information related to tissue depth to be displayed on the screen in a visually effective manner. An ultrasound transducer array operating in B- mode permits a picture of the tissues within a patients body to be displayed on a CRT device. M-mode ultrasound imaging presents tissue movement by scanning an A or B line on a varan as a function of time and movements in this line indicate movements in the tissues within the body. In C-mode ultrasound imaging a second transducer is used to detect echoes sent out by the first transducer, presenting a 2-D map of the ultrasound attenuation within tissues.Having discussed the principles of operation of a piezoelectric medical ultrasound transducer, it is now appropriate to consider the practical problems associated with the construction of such transducers. This is done below.The instauration of Ultrasound TransducersA transducer which is constructed out of piezoelectric material will have a natural frequency of resonance and it is appropriate that the transducer should be excited with alternating electric field which matches the natural resonant frequency of oscillation of the mate rial. The ultrasound frequencies that are used in medical imaging applications range from 1 MHz to 15 MHz and echocardiography is usually performed at frequencies of 2.5 MHz. Hence, transducers which are used for ultrasound imaging have to be tuned for different frequencies. For a transducer material in which ultrasound waves travel at the speed c, with a resonant frequency f, the ponderousness of the material is related by the formula f=c/2d. Hence, it is possible to tune various transducers constructed of the same material to different frequencies by adjusting the thickness of the material. The ultrasound transducer can be excited by a continuous wave, a pulsed wave, or a single voltage pulse depending on the requirements for observing a continuous image, echo ranging or other tissue measurements. The rear face of the piezoelectric crystal material is usually supported by a mount material which is tungsten loaded araldite, so that the vibrations in the piezoelectric material are rapidly damped after the initial excitation. It is important to couple the piezoelectric transducer to the body of a patient so that the incident ultrasound energy can be effectively transmitted into the body tissue that is being scanned. In order to do this, twin(a) layers of suitable acoustic material are used along with a gel which makes it possible for the ultrasound waves to penetrate the tissue more efficiently. As far as possible, the characteristic acoustic impedance of the tissue being scanned is matched with the acoustic impedance of the transducer. The characteristic acoustic impedance of the tissue is be asIn the formula, c is the speed of ultrasound in human tissue which is about 1540 m/sec with a variation of +/- 6% and is the tissue density. K is the bulk elastic modulus of the tissue being scanned.The acoustic parameters of an ultrasound transducer include its nominal frequency, the peak frequency which is the highest frequency response measured from the frequenc y spectrum, the bandwidth of the transducer which is the difference between the highest and the lowest 6 dB level in the frequency spectrum, the pulse width response time of the transducer, which is the time duration of the time domain envelope which is 20 dB above the rising and decaying cycles of a transducer response, the loop sensitivity for a medium on which a test is performed which is characterised byHere, Vo is the excitation pulse voltage in volts, while Vx is the received signal voltage from the transducer. The signal to noise ratio for a biomedical ultrasound transducer is also an important parameter for an ultrasound transducer and this is defined asIn the above expression, Vx is the received signal voltage from the transducer in volts in response to a qualify tone burst or pulse and Vn is the noise floor in volts. The signal to noise ratio for an ultrasound transducer is a measure of the noise associated with the transducer, beat instrument or cables and this is a go od measure of how sensitive a transducer is. In addition to the previously mentioned parameters, geometrical parameters for a transducer describe how the acoustic pressure generated by a transducer varies across the axial and cross-sectional fields of a transducer. These variations are illustrated belowAxial bare Profile for an Ultrasound TransducerCross sectional Beam Profile for an Ultrasound Transducerhe detailed construction of an ultrasound transducer for medical applications involving the shaping of the piezoelectric material, matching layers, hovictimization and backing materials etc is presently conducted using computational techniques such as Finite Element Modelling of ultrasound transducers through the use of software packages such as Ultrasim and other commercially forthcoming software. In the overall design, efforts have to be made to ensure that the overall design will be optimised so as to deliver a sufficiently high power of ultrasound into the tissue being image d and as far as possible there is best possible sound impedance matching between the transducer and the scanned tissue. Design of the backing material in an ultrasound transducer is important because this design determines the ring down time of the transducer, which is critical for low noise and best axial resolution of the transducer.Trends in Transducer Design for EchocardiographyOnly the simplest equipment for echocardiography will use a single ultrasound transducer and there is a trend towards design of echocardiography equipment which uses two or even three dimensional arrays of ultrasound transducers to provide superior quality 2 D or 3-D computer generated pictures of the organ being imaged. Even the relatively simpler equipment being used these days has two or more ultrasound transducers fitted into the transducer probe. The array of transducers are capable of generating a shaped channelise of ultrasound which can be appropriately focused using electronic digital signal pr ocessing techniques to provide better images and resolution. Although the relatively simple medical ultrasound scanners cost about 1000 per piece, reasonably decent transducer assemblies for a decent Philips or Toshiba ultrasound machines can cost 1500 for the transducer alone. Transducer arrays for two or three dimensional ultrasound imaging equipment can be much more expensive because of the large number of transducers that are employed in such imaging equipment.For better quality ultrasonic imaging to be possible, there is a requirement for enhanced bandwidth transducers, higher(prenominal) frequency transducer arrays and sophisticated digital signal processing circuits. There is also a trend towards transducer miniaturisation which will make intracavitary, intraurethral, or intravascular ultrasound (IVUS) investigation possible. The current imaging frequency range of 1 MHz to 15 MHz is expected to be increased to 20 MHz to 100 MHz and at these frequencies, microsonography device s using miniature ultrasound transducers with higher sensitivities are expected to provide much better and higher resolution images using catheter based transducers which are less then 2mm in diameter and are capable of being placed in veins. advanced ultrasound transducer materials are possible to provide transducers which are far more sensitive then those in stock(predicate) presently and consume lower power. These transducers can be operated from battery powered portable equipment and there are indications in literature that with the availability of such devices, it is likely that the stethoscope will be replaced by miniature ultrasound equipment. New trends in ultrasound transducer construction are also moving towards composite transducer construction in which a composite of two piezoelectric materials is used to design the transducer.Ultrasound transducers are fairly rugged and the piezoelectric material does not loose its properties unless undefendable to high temperatures approaching the Curie temperature for the material are reached or there are strong alternating or direct electrical fields argue the direction of poling for the material. Mechanical stresses imposed on the piezoelectric materials should not exceed the specified limits and although the specified limits vary for different types of materials, mechanical stress in prodigality of 2.5 MPa may be considered as likely to cause permanent damage. Ultrasound transducers are capable of being designed to operate in liquid mediums and the piezoelectric material does not react with water or gel.ConclusionMaterials with piezoelectric properties such as lead titanate (PbTiO3) and lead zirconate (PbZrO3) lend themselves to being treated by poling to generate as well as detect ultrasound waves when subjected to alternating electric fields or mechanical stresses. Ultrasound transducers can be made out of these materials and these transducers can be designed for specified resonance frequencies for us e in medical imaging. The detailed design of such transducers is an exciting and involving undertaking which is capable of being assisted by finite element simulations. Advances in transducer design involving the use of new materials, miniaturisation and the use of arrays of transducers promises to revolutionise medical imaging in the future by providing high resolution 3-D ultrasound images and the field is full of promise for device designers as well as computer engineers of the future.References/ Bibliography nett SourcesAbboud, Najib N et al. Finite Element Modelling for unhearable Transducers. Weidlinger Associates Inc. SPIE Int. Symp. medical imaginativeness 1998, San Diego, Feb 21-27, 1998. sublime 4, 2005. http//www.wai.com/AppliedScience/Software/Pzflex/Papers/pzflex-spie_mi98.pdfBinder, T. Three-Dimensional Echocardiography Principles and Promises. daybook of Clinical and Basic Cardiology 2002 5 (Issue 2), 149-152. August 4, 2005. http//www.kup.at/kup/pdf/1137.pdfBrand t, Einar. Segmentation Techniques for Echocardiographic Image Sequences. University of Linkopings. 1998. August 4, 2005. http//www.imv.liu.se/klinfys/einar/publications/pdf_open/Ex1934.pdfBridal, Lori S et al. Milestones on the Road to Higher Resolution, Quantitative, and Functional Ultrasonic visualise. PROCEEDINGS OF THE IEEE, VOL. 91, NO. 10, OCTOBER 2003. August 6, 2005. http//dei-s1.dei.uminho.pt/outraslic/lebiom/ultra/ultrasonic01232192.pdfDiederichs, Rolf. Ultrasound Transducer Library. Diederichs, Rolf. March, 1998. August 4, 2005. http//www.ndt.net/wshop/wshop_tr/trans_li.htmEberhard, Brunner. Ultrasound System Considerations and their Impact on Front-End Components, Analog Devices, Inc., 2002. August 4, 2005. http//www.analog.com/library/analogDialogue/archives/36-03/ultrasound/UltrasoundFrontend.pdfErikson, Kenneth R et al. Ultrasound in Medicine A Review. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, VOL. SU-21, NO. 3, JULY 1971. August 4, 2005. http//www.ieee-uffc.org/ ultrasonics/teaching/t7430144.pdfFink, Mathias. Time Reversed Acoustics. Scientific American Inc, 1999. August 4, 2005. http//www4.ncsu.edu/fouque/fink.pdfG. Fleury, R. Berriet, O. Le Baron, B. Huguenin. New piezocomposite transducers for therapeutic ultrasound. 2nd worldwide Symposium on Therapeutic Ultrasound Seattle 31/07 02/08/02. August 4, 2005. http//www.imasonic.com/Papers/ISTU2Ima.pdfGenadiy V. Leonov,, Vladimir N. Khmelev, Roman V. Barsukov, Sergey N. Tsyganok, Alexey N. Slivin, Andrey V. Shalunov. Advancement of Ultrasonic Technologies Efficiency, Development of Ultrasonic Devices for the Manufactures, medical checkup Institutions and the Agriculture Requirements. Biysk Technological Institute. 2004. August 4, 2005. http//www.bti.secna.ru/institute_/laboratory/us/downloads/vestnic_e.pdfGoel, Malti. Electret sensors, filters and MEMS devices New challenges in materials research. Current Science. Volume 85. No. 4. August 25, 2004. August 4, 2005. http//www.ias.ac.in/cur rsci/aug252003/443.pdfHazas, microphone and Andy Ward. A Novel Broadband Ultrasonic Location System. University of Cambridge, United Kingdom. 2002. August 4, 2005. http//www.comp.lancs.ac.uk/hazas/Hazas02_ANovelBULS.pdfHolm, Sverre. Ultrasim A Toolbox for Ultrasound Field Simulation. University of Oslo. 2000. August 6, 2005. http//heim.ifi.uio.no/sverre/ text file/01_Matlab.pdfKrochak, Paul and Stefan Story. Acoustic Densification of Multiphase Stream. University of British Columbia. June 19, 2005. August 4, 2005. http//www.math.ubc.ca/FluidLab/people/sstorey/Densificatio_Final_Report.pdfLadabaum, Igal et al. Surface Micro machined Capacitive Ultrasonic Transducer. ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 45, no. 3, may 1998. August 4, 2005. http//piezo.stanford.edu/library/papers/IL1998.pdfLewin, Peter A. diagnostic Ultrasound A Glimpse into the Next Decade. Drexel University. 2004. August 4, 2005. http//www.wma.net/e/publications/pdf/2000/lew in.pdfM. Greenstein, P. Lum, H. Yoshida, M.S. Seyed-Bolorforosh. A 2.5 MHz 2D Array with Z-Axis Electrically Conductive Backing. 2004. August 4, 2005. http//www.hpl.hp.com/techreports/96/HPL-96-89.pdfMeasurement Specialties Inc. Piezo Film Sensors Technical Manual. Measurement Specialties Inc. April 2, 1999. August 4, 2005. http//www.media.mit.edu/resenv/classes/MAS836/Readings/MSI-techman.pdfMichael Greenstein. Multilayer Piezoelectric Transducers for aesculapian Ultrasound Transducers. Hewlett Packard Laboratories. 2000. August 4, 2005. http//www.hpl.hp.com/techreports/95/HPL-95-79.psMorgan Electro Ceramics. Introduction Piezoelectric Ceramics. Morgan Electro Ceramics. May 16, 2001. August 4, 2005. http//www.morganelectroceramics.nl/pdfs/tech.pdfNorth Dakota State University. Imaging Systems. North Dakota State University. 2004. August 4, 2005. http//venus.ece.ndsu.nodak.edu/schroeder/Imaging%20Systems.docNottingham University. Medical Ultrasound. Nottingham University. 2004. Au gust 4, 2005. http//www.nottingham.ac.uk/physics/ugrad/courses/mod_home/f31ab1/notes/us.docPetersen R.B. and J. Hutchins. The iE33 intelligent echocardiography system. Philips Ultrasound Medical Systems. 2004. August 4, 2005. http//www.medical.philips.com/main/news/assets/docs/medicamundi/mm_vol48_no3/11_Peterson.pdfPicture IQ.com. Ultrasound Equipment. Picture IQ.com. 2005. August 6, 2005. http//www.pictureiq.com/piq/ph30-63999-Ultrasound.mspxPowis, Raymond. L and G. Wayne Moore. The Silent Revolution Catching up with the Contemporary Composite Transducer. JDMS 20395405 November/December 2004. August 4, 2005. http//www.medphysics.wisc.edu/mp666/powis_moore_contemp_trans.pdfRainer Stotzka, Helmut Widmann, Tim Muller, Klaus Schlote Holubek, Hartmut Gemmeke, Nicole Ruiter, Georg Gobel. Prototype of a new 3D ultrasound computer tomography system transducer design and data recording. Forschungszentrum Karlsruhe. 2004. August 4, 2005. http//www.stotzka.de/Publications/stotzka2004.1.pdfRA TSIMANDRESY, Leong, P.Mauchamp, D. Dinet, N. Felix, R. Dufait. A 3 MHz, Two Dimensional Array Based on Piezocomposite for Medical Imaging. IEEE Ultrasonics Symposium Proceedings. 2002. August 4, 2005. http//www.vermon.com/Biblio_Vermon/IEEE_3MHz%202D%20Array.pdfRitter, Timothy et al. Single Crystal PZN/PT-Polymer Composites for Ultrasound Transducer Applications. IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 47, no. 4, July 2000. August 4, 2005. http//www.ieee-uffc.org/archive/public/opapers/jul792.pdfRonald E McKeighen. Design Guidelines for Medical Ultrasonic Arrays. Acoustic Imaging Transducers Inc. 2000. August 4, 2005. http//www.wai.com/AppliedScience/Software/Pzflex/Papers-other/spie-man.pdfSaleh K. Y. and N.B. Smith. Two-dimensional ultrasound phased array design for tissue ablation for treatment of benign prostate hyperplasia. Pennsylvania State University. May, 2003. August 4, 2005. http//www.bioe.psu.edu/ultrasound/Research/Saleh%20Smith%20I JH04.pdfSchmidt, M. Ultrasonic Signal Processing Chip For Intraluminal Catheter Based Systems. Fraunhofer Institute of Microelectronic Circuits and Systems. 2004. August 4, 2005. http//www.imec.be/esscirc/papers-96/143.pdfShindler, Daniel M. Hand-held Ultrasound and the Stethoscope. Robert Wood Johnson Medical School. 2004. August 4, 2005. http//www.bbriefings.com/pdf/950/shindler.pdfUltran. Medical Ultrasonic Transducers. Ultran. 2004. August 4, 2005. http//www.ultrangroup.com/pdfs/ultran_trans_cat.pdfUniversity of Central London. An Overview of Existing Medical Imaging Techniques. University of Central London. 2004. August 4, 2005. http//www.medphys.ucl.ac.uk/research/borl/homepages/florian/thesis/pdf_files/p35_44.pdfUniversity of Lancaster. Medical Ultrasound Imaging. University of Lancaster. 2004. August 4, 2005. http//www.lancs.ac.uk/depts/physics/teaching/py336/Ultrasound.docWang, Haifeng, Tim Ritter, Wenwu Cao, and K. Kirk Shung. Passive Materials for High Frequency Ultrasoun d Transducers. The Society of Photo optical Instrumentation Engineers, SPIE. 1999. August 6, 2005. http//www.bioe.psu.edu/labs/NIH/pass_mat.pdfWeigang, Beate, G. Wayne Moore, M.A., crowd Gessert, William H. Phillips, Mark Schafer. The Methods and Effects of Transducer Degradation on Image Quality and the Clinical Efficacy of Diagnostic Sonography. Sonic Technology Laboratories. 2004. August 4, 2005. http//www.4sonora.com/products/Transducer%20Degradation%20on%20Image.pdfWells, P.N.T. Ultrasonic Imaging of the Human Body. Bristol General Hospital. 1999. August 4, 2005. http//www.hrcc.on.ca/Research/bios/people/pattersonfiles/Wells%20paper.pdfWhitehouse, Kamin. Fred Jiang, Chris Karlof, Alec Woo, David Culler. Sensor Field Localisation A Deployment and Emperical Analysis. University of California, Berkley. April 9, 2004. August 4, 2005. http//www.cs.berkeley.edu/kamin/pubs/whitehouse04ultrasoundUCBtechReport.pdfReferences Related to Ultrasound Transducers from British Libraries. Medi cal Imaging 1999 Ultrasonic Transducer Engineering 24-25 February 1999, San Diego, California. Bellingham, capital letter SPIE, 1999.. Medical Ultrasound Mirror Transducer Systems for High Resolution Imaging. 1984.American Association of Physicists in Medicine. Medical Physics of CT and Ultrasound Tissue Imaging and Characterization Summer School Papers and Discussions.American Institute of Ultrasound in Medicine. Ultrasound apply Committee Report for Cleaning and Preparing Endocavitary Ultrasound Transducers Between Patients. Laurel, Md. American Institute of Ultrasound in Medicine, 1995.American Society of Ultrasound Technical Specialists and Society of Diagnostic Medical Sonographers. Medical Ultrasound. New York Wiley.Barnett, S. B., G. Kossoff, and World Federation for Ultrasound in Medicine and Biology. Safety and Standardisation in Medical Ultrasound Issues and Recommendations Regarding Thermal Mechanisms for biological Effects of Ultrasound Symposium Papers. Pergamon Press , 1992.British Medical Ultrasound Society. BMUS Bulletin. London British Medical Ultrasound Society, 2003.Davies, Christopher Mark. The Construction and Design Characteristics of Bimorph Shear Wave Transducers. 1993.Fleming, David G., et al. Indwelling and Implantable military press Transducers Based on Workshop Held in Cleveland, Ohio on December 4 and 5, 1975, Sponsored by the Biotechnology Resources Branch (RR-00857) and the bailiwick Institute of General Medical Sciences (GM-14267) of the National Institutes of Health. Cleveland CRC Press, 1976.Great Britain. Medical Devices Agency. A Comparative Technical Evaluation of Eleven Ultrasound Scanners for Examination of the Breast. Medical Devices Agency, 2001.Kuhn, A., P. A. Payne, and Dias. Design and Construction of Ultrasound Equipment for Characterization of elasticized Mechanic Properties of Dental Restorative Materials. Manchester UMIST, 1991.Luukkala, Mauri. Second Harmonic Generation of Ultrasound in Quartz Transducers. T urku, 1967.Mok, W. H., M. S. Beck, and Dias. Flow Imaging Using Pulsed Ultrasound Transducers. Manchester UMIST, 1986.Nakano, Hitoo, et al. XX International Congress The Fetus As a Patient and 6th Ian Donald Inter-University of Medical Ultrasound. 2004.Nicoll, J. J. and University of Edinburgh. Medical Ultrasound Mirror Transducer Systems for High Resolution Imaging. University of Edinburgh, 1984.Preston, R. C., et al. The Performance of the NPL Ultrasound Beam Calibrator Part 1 Physiotherapy Transducers. Teddington National Physical Laboratory, 1986.Ruttenberg, Robert and Simon Peck. Transducer Development for Medical Dynamic Measurements. 2000.Shung, K. Kirk and Society of Photo-optical Instrumentation Engineers. Medical Imaging 1998 Ultrasonic Transducer Engineering 25-26 February 1998, San Diego, California. Bellingham, Washington SPIE, 1998.Society of Diagnostic Medical Sonographers. JDMS Journal of Diagnostic Medical Sonography. Philadelphia Lippincott for the Society of Diagn ostic Medical Sonographers.Society of Ultrasound in Medicine of the Republic of China. Journal of Medical Ultrasound. Taipei.Turnbull, Daniel H. and University of Toronto Department of Medical Biophysics. Two-Dimensional Transducer Arrays fo
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.